Synthes va prox tibia inventory

Diseño universal para la tibia derecha o izquierda. Material: Titanio, 6%; aluminio, 7%; aleación de niobio (TAN) Diámetros: De 8 a 13 mm (incrementos de 1 mm) Los clavos de 8 a 10 mm tienen un diámetro proximal de 11 mm. Los clavos de 11 a 13 mm tienen un diámetro proximal compatible con el diámetro del vástago..

VA-LCP Proximal Tibial Plate 3.5 VA-Locking Calcaneal Plates 2.7 VA-Locking Intercarpal Fusion System Variable Angle LCP 1st MTP Fusion Plates 2.4/2.7 ... Synthes has not tested compatibility with devices provided by other manufacturers and assumes no liability in such instances.Inventory; Delete Set. Manage Set Trays and Contents Save Changes. UNIVERSAL SMALL FRAGMENT VA-LCP PROX TIBIA SET EVAL Add Tray Kit Trays and Contents Collapse All Expand All. Primary Tray (34 Parts) Add products to tray Move To; Top of the kit; Bottom of the kit ...

Did you know?

In contrast, the capturing rates boosted to 76.4% and 71.5% when utilizing VA screws in the DePuy Synthes VA-LCP and the Biomet plate. The high-frequency uncaptured areas tended to concentrate on the rim of the posterolateral wall and were mainly distributed in the posterior 1/2 to 3/4 of the parallel position of the fibula head.Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.The TOMOFIX ™ Osteotomy System is a comprehensive plating system for stable fixation of osteotomies around the knee with locking compression technology. Its five plates are designed for fixation of fractures and osteotomies of the distal femur and proximal tibia. Product Specifications.About This Product. The system consists of three plate types, each one available in left and right version: Lateral Plate. Shaft Plate. Medial Plate. The VA LCP Clavicle Plates are made up of stainless steel and titanium alloy. The holes of the plates accept 2.7 mm cortex screws, 2.7 mm VA locking screws and 2.7 mm metaphyseal compression screws.

The Universal Small Fragment (USF) System is intended to be used for small bone trauma, including anatomy such as Shoulder, Clavicle, Elbow, Tibia and Fibula. The core set can support any DePuy Synthes 2.7mm or 3.5mm non-locking, LCP® or VA LCP® Implant System. Training topics for USF. System Trays. Instruments.quarter (lateral and medial) of the tibia as well as segmental fractures of the proximal tibia. The 4.5 mm version may also be used for fixation of nonunions and malunions of the medial proximal tibia and tibia shaft, as well as opening and closing wedge tibial osteotomies. 6 Synthes Large Fragment LCP Instrument and Implant Set Technique GuideConsult Depuy Synthes's entire LCP Distal Femur / Promixal Lateral Tibia 4.5 catalogue on MedicalExpo. Page: 1/12. Exhibit with us {{>currencyLabel}} Back ... Insert the locking screw through the guiding block. 6 Synthes LCP DF and PLT . Open the catalog to page 8. Product Information Note: Long LCP DF plates from 15-19 holes are available in ...proximal Holding Sleeve in the End Piece with double joint (5), and correct the angulation. 10 Synthes The AO ASIF Large Distractor—Femur 5 5 Compression Instrument 321.17 4.5 mm Pin Wrench Loosen the proximal Spindle Nut (2). Under image intensifi-cation, apply compression by moving the distal Spindle Nut (1) proximally.

• LCP Medial Proximal Tibia Plate 4.5/5.0 Locking Compression Plate The Locking Compression Plate (LCP) has combi-holes in the plate shaft that combine a dynamic compression unit (DCU) hole with a locking screw hole. Note: More detailed information on conventional and locked plating principles can be found in the DePuy SynthesVA-LCP Proximal Tibial Plate 3.5 VA-Locking Calcaneal Plates 2.7 VA-Locking Intercarpal Fusion System Variable Angle LCP 1st MTP Fusion Plates 2.4/2.7 ... Synthes has not tested compatibility with devices provided by other manufacturers and assumes no liability in such instances. ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Synthes va prox tibia inventory. Possible cause: Not clear synthes va prox tibia inventory.

4.5 mm LCP® Medial Proximal Tibia Plates Surgical Technique DePuy Synthes 3 4.5 mm LCP Medial Proximal Tibia Plates Three locking screw holes accept 5.0 mm cannulated locking or 5.0 mm cannulated conical screws Combi holes combine a DCU hole with a threaded locking hole Two 2.0 mm holes for K-wires and sutures Angled locking holes acceptEvan Goldberg of Oracle NetSuite discusses the new challenges of Just in Time inventory. About this time every year I look forward to heading to Oracle NetSuite’s annual user confe...

DESCRIPTION. The Titanium Cannulated Tibial Nail-Ex offers a variety of proximal and distal locking options for tibial fractures, allowing the surgeon to tailor fixation to the fracture pattern. The system has a universal design, allowing use on the left or right tibia. Product Specifications. How to Use This Product.Distal Tibia and Fibula Plates 2.7/3.5. The system comprises LOQTEQ® distal tibia plates for medial and anterolateral application as well as lateral distal fibula plates. Number and placement of plate holes as well as the screw trajectories are designed for treatment of a wide range of fracture types. The distal design respects the minimal ...The aim of this study was to evaluate the clinical and/or radiologic outcome using different polyaxial locking plates for the treatment of proximal tibia fractures, the Non-Contact-Briding plate (NCB-PT®) by Zimmer or the Variable Angle Locking Compression Plate (VA-LCP®) by Synthes. This study enrolled 28 patients with proximal tibia fractures (AO/ OTA 41 B-C) and indication for locking ...Synthes 9 5 Schraubenlänge bestimmen Durchbohrte Schraube 3.0/3.5/4.0 Den Messstab für durchbohrte Schrauben bis zur Kortikalis vor-schieben. Die passende Schraubenlänge direkt am Messstab ablesen. Durchbohrte Schraube 4.5/6.5/7.0/7.3 Die Gewebeschutzhülse einbringen und den Messstab über den Führungsdraht bis zum Knochen vorschieben. DieINVENTORY CONTROL FORM 3.5 mm LCP ® Distal Tibia T-Plate 3.5 mm LCP Distal Tibia T-Plates HOLES 02.112.203 3 02.112.205 5 2.7 mm Cortex Screws, self -tapping ... Case Information: Synthes USA, LLC Synthes (Canada) Ltd. To order: (800) 523-0322 To order: (800) 668-1119. INVENTORY CONTROL FORM

Our LCP™ Distal Tibia Plates are part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plates feature Combi holes, allowing fixation with locking or cortex screws. Product Specifications. How to Use This Product.4ePuy D Synthes 3.5 mm LCP® Clavicle Hook Plates Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which

Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle Plate System 2.7 mm VA LCP Clavicle Plates Lateral Stainless Steel Titanium Plate Size Left/Right 02.112.61004.112.610 Left CS1 02.112.61104.112.611 Right CS1 02.112.61204.112.612 Left CS2 02.112.61304.112.613 Right CS2 02.112.61404.112.614 Left CS3 02.112.61504.112.615 Right CS3The DePuy Synthes VA Locking Attachment Plate 3.5 is offered in Stainless Steel mate - rial in both sterile and non-sterile package configurations. It attaches to DePuy Synthes VA-LCP PPFx Proximal Femur Plate or Proximal Femur Hook Plate 3.5/4.5/5.0, VA-LCP Curved Condylar 4.5/5.0, LCP Curved Condylar 4.5/5.0, Straight and Curved Broad LCPDiscover DePuy Synthes portfolio of Trauma & Extremities solutions. Our products offer options for treating fractures and a wide range of deformities. ... Proximal Tibia (24) Foot & Ankle (42) Fibula (17) Distal Tibia (28) Midfoot/Hindfoot (20) Forefoot (13) ... 2.7 MM VA LCP™ CLAVICLE System. A clavicle plate system that consists of three ...

suite 116 harlem ny Tibia Plate with locking screws. 2.7 mm or 3.5 mm cortex screws may also be used as lag screws through the plate by overdrilling the near fragment. Note: To verify that independent lag screws will not interfere with plate placement, evaluate placement with AP and lateral fluoroscopic image. LCP Distal Tibia Plate • Surgical Technique 5Important: Determine proximal screw placement and screw lengths to ensure proper screw placement in the metaphysis. Position the patient supine on a radiolucent operating table. Visualization of the proximal tibia under fluoroscopy in both the lateral and AP views is necessary. 6 Synthes 3.5 mm LCP Medial Proximal Tibia Plates examples of acts retreat love letters 3.5 mm VA-LCP Proximal Tibia Plates, Small Bend HOLES LENGTH SIDE 02.127.310 4 87 mm right 02.127.311 4 87 mm left 02.127.320 6 117 mm right 02.127.321 6 117 mm left 02.127.330 8 147 mm right 02.127.331 8 147 mm left 02.127.340 10 177 mm right 02.127.341 10 177 mm left 02.127.350 12 207 mm right 02.127.351 12 207 mm left 02.127.360 14 237 mm right maine anon images VA-LCP® by Synthes (West Chester, Pennsylvania, USA), used for the treatment of complex proximal tibia fractures. Methods Patients Prior to the onset of the study, the approval by the med-ical ethics committee of the Technical University of Munich (TUM) (Trial Number: 5923/13) was obtained. During a period from October 2013 to December 2015Tibial plateau fracture: Posterior column fracture fixed with Synthes proximal tibial LISS plate Tibial plateau fracture: Fixation of a bicondylar fracture with a dual incision technique (Smith and Nephew EVOS plates) rivertown movies DESCRIPTION. LCP™ Proximal Tibia Plates merge conventional plating techniques with locking screw technology to enable surgeons to create a fixed-angle construct while using familiar plating techniques. They are available in 3.5- and 4.5-mm sizes to accommodate a variety of fractures. Product Specifications. How to Use This Product.About This Product. The Synthes Olecranon Plates System consists of VA-LCP Proximal Olecranon Plates, VA-LCP Proximal Olecranon Plates and VA-LCP Proximal Ulna Plates and different type of Screws used with the plate. Such as. Locking Screws Ø 3.5 mm. Cortex Screws Ø 3.5 mm. Low Profile Cortex Screws Ø 3.5 mm. VA Locking Screw Ø 2.7 mm. dental care at winnowing way The Expert Tibial Nail permits an intra medullary approach for the fixation of proximal, shaft and distal fractures of the tibia. The system consists of a series of cannulated nails, can-nulated end caps, dual core locking screws and standard locking screws. All of the implants are made of titanium alloy (TAN*). ai 173 delhi to san francisco flight status Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.Die LCP Mediale Distale Tibiaplatte Low Bend 3.5 mm gehört zum Synthes LCP Kleinfragment-System, das Verriegelungs-schraubentechnologie mit herkömmlichen Verplattungstech-niken kombiniert. Die Kombilöcher im Schaft der LCP-Platte kombinieren ein DCU-Loch (Dynamic Compression Unit) mit einem Verriege-lungsschraubenloch. stradman cars The LCP Anterolateral Distal Tibia Plate is part of Synthes Distal Tibia Plates family. These plates are available as stainless steel or Commercially Pure titanium, in right and left configurations, with 5 to 21 holes and lengths from 80 to 288 mm. ... 2.7 MM VA LCP™ CLAVICLE System; 2.7/3.5mm Variable Angle LCP® Elbow System; 3.5 mm LCP ... horses for sale california craigslist Synthes 3.5mm LCP Posteromedial Proximal Tibia Plates are indicated for internal fixation of posteromedial proximal tibia fractures including buttressing of fractures of the proximal, distal, and metaphyseal areas of the tibia. Prescription Use X AND/OR Over-The-Counter Use (Per 21 CFR 801.109) (21 CFR 807 Subpart C) ... alex bednar hibbing mn Mar 18, 2021 · The NCB-PT® as well as the VA-LCP® allows a variation of screw positioning within specified limits. Besides these two products there are numerous other polyaxial plate systems for the proximal tibia available. However, at the current moment there are no prospective studies including different polyaxial locking plates in proximal tibial fractures. 381 main st saugus mapulte briarwood 4ePuy D Synthes 3.5 mm LCP® Medial Proximal Tibia Plates Surgical Technique AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which ... guild vendor valdrakken A – Stryker AxSOS 3 Ti Proximal Tibia plate; B – Smith & Nephew PERI-LOC Lateral Proximal Tibia plate; C – DePuy Synthes 3.5mm Variable Angle Locking Compression Plate [VA-LCP] Proximal Tibia plate – fixed trajectory; D – DePuy Synthes 3.5mm VA-LCP Proximal Tibia plate – VA screws aimed toward the PMF; E – Zimmer Biomet A.L.P.S ...Inventory Control Form 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 2.7 mm / 3.5 mm Variable Angle LCP Medial Distal Tibia Plates 02.118.002 4 holes, right 02.118.003 4 holes, left 02.118.004 6 holes, right 02.118.005 6 holes, left starz oil co new jersey 3.5 mm VA LCP® Proximal Tibia Plate System Surgical Technique DePuy Synthes 9 PLATE INSERTION AND FIXATION 1 Determine plate type Instruments 03.127.012 3.5 mm VA-LCP Proximal Tibia Trial Implant, Small Bend, Right 03.127.013 3.5 mm VA-LCP Proximal Tibia Trial Implant, Small Bend, Left 03.127.014 3.5 mm VA-LCP Proximal Tibia TrialLCP™ Proximal Femur Plate (4.5/5.0mm) Variable Angle LCP™ Ankle Trauma System (2.7 mm/3.5 mm) 3.5 mm LCP ® Anterolateral Distal Tibia Plates; 3.5 mm Variable Angle LCP ® Proximal Tibia Plate; 4.5 mm LCP ® Proximal Tibia Plate; Continuous Compression Implants for Trauma Applications; TomoFix ® Medial High Tibia Plate; Power Tools. UNIUM ... corey dolliver haverhill ma The Variable Angle LCP™ Forefoot-Midfoot System offers a wide range of low-profile plates with variable angle (VA) screw placement and compression system designed within the plates to help minimize additional soft tissue dissection. Available in stainless steel and titanium. Product Specifications.The Expert Tibial Nail permits an intra medullary approach for the fixation of proximal, shaft and distal fractures of the tibia. The system consists of a series of cannulated nails, can-nulated end caps, dual core locking screws and standard locking screws. All of the implants are made of titanium alloy (TAN*). black owned nail salons baltimore Like the weather, the housing market usually cools in the fall. Will the coronavirus make this year different? By clicking "TRY IT", I agree to receive newsletters and promotions f... 800 howard ave new haven parking The new templates will be made available worldwide in a sequential manner beginning early 2021. Japan, Germany, the United Kingdom, and the Nordic countries are among those markets where the templates will be released first. Fig 1 Anatomic template for the 11-hole LCP® Anterolateral Distal Tibia plate. Fig 2 Radiopaque appearance of the ...UNIVERSAL SMALL FRAGMENT VA-LCP PROX TIBIA SET EVAL. Add Tray. Kit Trays and Contents Collapse All Expand All. Primary Tray (34 Parts) Add products to tray. maggie beth phelps wedding Sehen Sie den gesamten Katalog LCP Distal Femur / Promixal Lateral Tibia 4.5 der Firma Depuy Synthes auf MedicalExpo. Seite: 1/12. Aussteller werden ... for Distal Femur (036.000.235) - Proximal Lateral Tibia: See technique guide Less Invasive Stabilization System (LISS) for Proximal Lateral Tibia Using the guiding blocks for LCP DF and PLT The ... e1 code on pellet stove The DePuy Synthes 4.5 mm LCP® Condylar Plate is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. The LCP Periarticular Plating System is capable of addressing complex fractures of the distal femur with the 4.5 mm LCP Condylar Plates, complex fractures of the proximal femurIn epiphyseal fractures the condyles or the pilon tibiale are fixed first in order to enable the nail insertion. 10 Synthes Expert Tibial Nail Technique Guide. Open the catalog to page 12. 3 Confirm nail length and diameter Instrument 03.010.021 Radiographic Ruler for Tibial Nails, length 450 mm The required nail length must be determined after ... is rio da yung in jail Methods: We conducted a prospective study on closed reduction and percutaneous plating in 30 cases (mean age 42.7 years; 22 males and 8 females) of closed fractures of tibia. Among them 24 had proximal tibial fractures and 6 had distal tibial fractures. The mean time from injury to surgery was seven days. jordan vilines Sistema de osteosíntesis con premoldeado anatómico y estabilidad angular para diafisarias y laterales de clavícula. Placa VA-LCP 2.7/3.5 para clavícula anterior, lateral (7, 9, 10, 11 y 12 agujeros) Agujeros del cuerpo. Para tornillos de bloqueo de 3.5 mm, tornillos de cortical de 3.5 mm o tornillos de esponjosa de 4.0 mm.The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.The 3.5 mm LCP Proximal Tibia Plates have a limited-contact profile. The head and neck portions of the plates accept 3.5 mm StarDrive™ Recess Locking Screws. The screw hole pattern allows a raft of subchondral locking screws to buttress and maintain reduction of the articular surface. This provides resistance to local depression loads in ...]